Vacuum Insulated Pipe Specifications
| Vacuum Insulated Pipe Size | Heat Leak BTU per Hour |
||||
|---|---|---|---|---|---|
| Inner Pipe | Outer Pipe | Outer Diameter | Wt./Ft. | Pipe | Bayonet |
| .5″ | 2″ | 2.375″ | 2.4 lb | .32/ft | 9.5 |
| 1″ | 2.5″ | 2.875″ | 3.7 lb | .42/ft | 14.0 |
| 1.5″ | 3.0″ | 3.5″ | 4.7 lb | .54/ft | 12.9 |
| 2″ | 3.5″ | 4.0″ | 5.6 lb | .74/ft | 18.6 |
All pipe sizes shown below are Type 304 Stainless Steel Sch 5 Pipe.
MAWP (Maximum Allowable Working Pressure) of the inner pipe is 150PSI for products listed.
Cryofab has the experience to manufacture efficient vacuum jacketed cryogenic piping to your specifications. In addition to rigid vj piping we offer flexible transfer hose with or without vacuum insulation.
Piping systems can include vacuum jacketed valves from Cryocomp. Options for valves include actuated functions and positioners for remote operation. See more cryogenic valve options and configurations on cryocomp.com.
Cryogenic bayonets for low heat leak connections are also available from Cryocomp.
Contact us at [email protected] or